Client Utility Services - Specifications
| Exhibit Hall Lighting |
| Location |
Description |
| Halls: A, B, C |
1,000 Watt metal halide on 30' centers |
| Hall: C |
90 Watt incandescent lamps in clusters of (4) on dimmers on 30' centers |
| Hall: D |
400 Watt metal halide on 20’ centers |
| |
| Ceiling Load and Height |
| Location |
Ceiling Load |
Ceiling Height |
| Halls: A, B, C |
250 lbs per Hang Point |
Low Clearance - 29', High Clearance - 51' |
| Hall: D |
250 lbs per Hang Point |
Low Clearance - 15', High Clearance - 21' |
| |
| Floor Load |
| Location |
Description |
| Halls: A, B, C |
350 lbs. psf |
Grand Hall
and Ballroom |
Grand Hall and Ballroom live load not to exceed 100 pound per square foot. Grand Hall maximum concentrated load not to exceed 4,800 pound any point with no other live load in area. Ballroom maximum concentrated load not to exceed 3,000 pounds at any point with no other live loads in area. |
| |
| Columns |
| Location |
Description |
| Halls: A, B, C |
On 120' centers |
| Hall: D |
On 60' centers |
| |
| Loading Docks & Drive-In Ramps |
| Location |
Description |
| Hall: A |
14 Docks; 1 Drive-In Door (29'h x 25'w) |
| Hall: B |
7 Docks; 1 Drive-In door (16'h x 25'w); 1 roll up door at front of hall (8'h x 14'w) |
| Hall: C |
6 Docks; 1 Drive-In door (29'h x 25'w) |
| Hall: D |
9 Docks; 1 Drive-In door (16'h x 25'w) |